Solution:
A 3/8" HO Series Turbine Flowmeter for Gas to meter
air.
Flowmeter Model# HO 1/2 x 3/8-15-B-1MC2PAX-MS
Operating Temp: +70 F.
Operating Pressure Range: 40 to 50 PSIG.
Flow Range: .5 to 5 ACFM.
Model ACC32-1-C-D-X-4/0 Flowmeter signal conditioner/converter
with 4-20 ma analog option. This conditioner with the
modulated carrier pickup coil improves turbine flowmeter
rangeability. The enclosure
type is style 4 which is integrally mounted on the meter
and suitable for hose down.
Hoffer Advantage: The Hoffer flow
system offers an economical and accurate solution
for air measurement. It is easily incorporated into
the customer's operation. The 3/8" gas turbine
flowmeter teamed with the ACC32 provides the user
with a metering system that yields wide rangeability,
long term accuracy, and flowmeter linearity of ±1%
or better. The response time of the HO meter is approximately
7 to 10 milliseconds..
Summary: The flow system allows
the customer to accurately measure air and is incorporated
into their operation easily. This process is much
like the use of a spray gun, with the flowmeter measuring
the amount of air to control the amount of liquid
necessary to coat the pills. The ACC32 signal conditioner/converter
sends a signal representative of flow rate back to
the customer's data acquisition center for process
control.
|